Product code
13003

HydroSure MiniPro® ½” Rotor Sprinkler – 4”

(750 LPH & 11m Radius)
383 In Stock
A PC rotor with 5 interchangeable nozzles adjustable in all stages of operation for flexibility, ultimate coverage and water-saving efficiency. See Full Description
£10.20 £8.50
(Ex. VAT) (Inc. VAT)

A PC rotor with 5 interchangeable nozzles adjustable in all stages of operation for flexibility, ultimate coverage and water-saving efficiency.

Solutions that Work

For Top Tips on how to install an underground sprinkler irrigation system, read our Buyers Guide.



HydroSure - In Partnership with K-Rain

Time-Proven Patented Reversing Mechanism

HydroSure, in partnership with K Rain’s 35 years of experience, have created a long-lasting pop-up sprinkler system that ensures continuous reverse and return minimising sticking or wear. Features a 4-inch pop-up riser that keeps the rotating nozzle clean and fully operational over time. For ever-changing watering requirements, the stainless steel adjustment radius screw will stand the test of time even after multiple adjustments and the rubber turret cover seals out dirt for increased product durability. The sprinkler also features easy clean mechanisms that can be extracted and cleaned during system maintenance.

Ultimate Irrigation Control

Arrives complete with a revolutionary top arc set-up designed to allow for wet or dry adjustment in a matter of seconds! For complete control over garden watering, the sprinkler is adjustable in all stages of installation; from before installation, after installation while static and after installation while in operation. To adjust the arc, simply twist the ratcheting riser from the left starting position clockwise to increase the degree arc or anti-clockwise to decrease.

Easy Arc Setting

The MiniPro® features an easily readable indication arrow that points directly to where the spray pattern is set and distinct degree markings simplify the arc adjustment by indicating the sprinklers wetting pattern. The sprinkler should be adjusted from the left starting position before adjusting the arc between 40° and 360° with just the simple turn of a riser. The sprinkler arrives with a pre-set 40° arc setting preinstalled with a 1.5 nozzle. To adjust, use alongside the HydroSure Key (not included).

Durable Pop-Up Sprinkler System

Manufactured with a five-year warranty and designed to provide year after year high performance and low maintenance. Engineered from corrosion and impact-resistant heavy duty ABS plastic for superior structural strength and enhanced weatherability for an underground system that can be trusted to last. The stainless steel spring is built for positive retraction of the riser when irrigation is complete ensuring protection against surface damage.

Low-Pressure Pop-up Irrigation System

Functions at optimal pressures between 1.4 – 4.8 bar making it the ideal solution for small domestic pop-up irrigation systems and at-home garden watering.


Specifications

  • Inlet: ½” Female Thread
  • Arc Adjustment Range: 40° - 360°
  • Flow Range: 180 – 750 Lph
  • Pressure Rating: 1.4 – 4.8 Bar
  • Precipitation Rate: 6.6 – 15.24 mm/h
  • Overall Height (popped down): 4”
  • Recommended Spacing: 5.2 – 10.4 metres
  • Radius: 5.5 – 11 metres
  • Nozzle Trajectory: 25°
  • Riser Height: 4”
  • Starting Position: Left


Pop-up Rotor Sprinklers Frequently Asked Questions

  • Why is Water Pooling Around the Sprinkler Site?

    • Underground systems require frequent flushing to prevent dirt from clogging the nozzle or damaging the seal. Flush the system and clean the rotors if necessary to remove any sitting sediment.
    • Any damage to the riser caused by a mower or footfall will cause mechanical malfunction and disfigured spray patterns. Check each nozzle and turret top of your sprinklers to ensure they are intact.
    • The area around a sprinkler site may become boggy/waterlogged indicating a loose connection between the swing joint/fitting or a break in the pipe network. To repair a leak, use a Compression Joiner/Joiner depending on the pipe used or install PTFE Tape around any male threaded connection to ensure a watertight seal.
    • Water leaking from sprinkler sites even when the system is switched off indicates a problem called low head drainage. A pop-up sprinkler with a Check Valve will prevent water pooling from sprinklers installed at the lowest elevation.
  • My Sprinklers are not Working the Same as when Purchased!

    • Over time a sprinkler may experience a build-up of sediment and debris that blocks the nozzle outputs or damages the riser retraction mechanisms inside the sprinkler. Flush the system and clean out the rotor sprinkler as explained in our Sprinkler Maintenance Guide.
    • Prevent debris build-up by installing an Irrigation Filter at the start of the system.
      • Alternatively, leaking connections or a pipe supplying the sprinkler may have split. The water lost from connections that are not watertight will cause pressure loss and reduce performance.
  • Why are my Underground Pipe Connections Leaking?

    An area that is boggy or waterlogged indicates a leaking connection or a pipe that may have split. Most connection points can be tightened by hand or by adding two wraps of PTFE Tape around male threads or replacing connectors that over time, have snapped.

    When fixing your pipe network, depending on the pipe you are using to supply your system will indicate the type of connector you need to repair the damage.

    LDPE Supplied Systems: Read our Repairing Damaged LDPE Irrigation Pipe Guide.

    MDPE/HDPE Supplied Systems: Read our Repairing a Leak Using a Compression Coupling Guide.

  • My Sprinkler Does Not Cover the Range/Radius Outlined in the Specifications

    A variation in flow rate or pressure drop from the water source will also reduce the performance of sprinklers – Check the flow rate from your tap remains high enough during the time of day your system is set to run using our Calculating Flow Rate from the Water Source Guide.

    • On windy days, the spray pattern from your sprinklers may alter even when using nozzles with built-in wind resistance. Alternatively, running a system at a bar pressure that is too high, will create misting – Consider installing a Pressure Reducer regulated as specified in the sprinkler specifications to minimise spray pattern wind drift.
  • How do I Lift the Riser of a Pop-up Sprinkler?

    To lift the riser of a rotor sprinkler, most require a Key inserted into the turret top of the sprinkler to lock into the mechanism and allow easy uprooting of the riser by hand. Any maintenance or switching of nozzles is often carried out in this way. Alternatively, ask a friend to switch the system on manually and catch the riser as it lifts during system operation.

Product Specification
Product Code13003
EAN5056287720129
Sprinkler Spray Radius10.1m
BSP Thread Size½ Female
Pressure Range1.4 Bar to 4.8 Bar
Manufacturer's Guarantee5 Years
Connection TypeThreaded
Pop-Up Height4"
Price Per Unit (Inc. VAT)10.20
Downloads

Customers who bought this item also bought

Look for similar items by category Browse for more related products in: